DPH Series

2 products

  • Delta DPH Series: Three-Phase UPS System (UPS) - DPH 200kW

    Three-Phase UPS System (UPS),Series:Modulon DPH Series,Cabinet Rated Capacity:200kW,Selectable Power Module Capacity:25kVA/50kVA/100kVA/125kVA/150kVA,Rated Input Voltage:380/220V/400/230V/415/240V(Three-Phase Four-Wire+Ground Wire),Input Voltage Range:176~276Vac/305~477Vac,Input Current Total Harmonic Distortion:<3%,Input Power Factor:>0.99,Input Frequency:50/60Hz,Rated Output Voltage:380/220V/400/230V/415/240V(Three-Phase Four-Wire+Ground Wire),Output Voltage Harmonic Distortion:≤2%(Linear Load),Output Voltage Stability:±1%(Static),Output Frequency:50Hz or 60Hz,Output Frequency Stability:±0.05Hz,Overload Capacity:≤125% Continuous 10 min/≤150% Continuous 1 min,Standard Interface:Parallel Port×2/Smart slot×2/Dry Contact Output×6/Dry Contact Input×6/SNMP Card×2/Battery Dry Contact×6,Optional Interface:SNMP Card IPv6×1/ModBus Card×1/Relay I/O Control Card×1/EnviroProbe×1/Battery Cabinet Temperature Detector×1/Battery Cabinet Status Cable×1,Certification:CE/EN62040-1,Parallel Redundancy Expansion:Max. Parallel Units 4 x (Max. Capacity 800kW),Emergency Power Off (EPO):Local and Remote,Battery Start:Supports,Event Log:3000 records,External Battery Cabinet:Optional,AC-AC Efficiency:96%(TÜV Test),ECO Economy Mode Efficiency:99%,Operating Temperature:0~40℃,Relative Humidity:0~95%(Non-Condensing),Noise:<62dBA(1 m ahead),Dimensions:600×1090×2000mm,UPS System Weight:350kg,Power Module Weight:32kg,Rack-Mount Precision Distribution Module:Not Applicable

    $55,714.29

  • Delta DPH Series: Three-Phase UPS System (UPS) - DPH 150kW

    Three-Phase UPS System (UPS),Series:Modulon DPH Series,Cabinet Rated Capacity:150kW,Selectable Power Module Capacity:25kVA/50kVA/100kVA/125kVA/150kVA,Rated Input Voltage:380/220V/400/230V/415/240V(Three-Phase Four-Wire+Ground Wire),Input Voltage Range:176~276Vac/305~477Vac,Input Current Total Harmonic Distortion:<3%,Input Power Factor:>0.99,Input Frequency:50/60Hz,Rated Output Voltage:380/220V/400/230V/415/240V(Three-Phase Four-Wire+Ground Wire),Output Voltage Harmonic Distortion:≤2%(Linear Load),Output Voltage Stability:±1%(Static),Output Frequency:50Hz or 60Hz,Output Frequency Stability:±0.05Hz,Overload Capacity:≤125% Continuous 10 min/≤150% Continuous 1 min,Standard Interface:Parallel Port×2/Smart slot×2/Dry Contact Output×6/Dry Contact Input×6/SNMP Card×2/Battery Dry Contact×6,Optional Interface:SNMP Card IPv6×1/ModBus Card×1/Relay I/O Control Card×1/EnviroProbe×1/Battery Cabinet Temperature Detector×1/Battery Cabinet Status Cable×1,Certification:CE/EN62040-1,Parallel Redundancy Expansion:Max. Parallel Units 4 x (Max. Capacity 800kW),Emergency Power Off (EPO):Local and Remote,Battery Start:Supports,Event Log:3000 records,External Battery Cabinet:Optional,AC-AC Efficiency:96%(TÜV Test),ECO Economy Mode Efficiency:99%,Operating Temperature:0~40℃,Relative Humidity:0~95%(Non-Condensing),Noise:<62dBA(1 m ahead),Dimensions:600×1090×2000mm,UPS System Weight:320kg,Power Module Weight:32kg,Rack-Mount Precision Distribution Module Weight:32kg

    $42,857.14

Footer image

© 2026 DELTA, .

  • US (USD $) US (USD $)
  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa