DPS Series

2 products

  • Delta DPS Series: Three-Phase UPS System (UPS) - DPS-500K

    Delta DPS Series: Three-Phase UPS System (UPS) - DPS-500K

    Three-Phase UPS System (UPS),Series:Ultron DPS Series,Rated Capacity:500kVA/450kW,Input Voltage:380/220Vac(3-Phase/4 Cable+Ground),Input Voltage Range:242~477Vac,Input Current Total Harmonic Distortion:≤3%,Input Power Factor:>0.99,Input Frequency:50/60±5Hz,Output Voltage:380/220Vac(3-Phase/4 Cable+Ground),Output Voltage Harmonic Distortion:≤1.5%(Linear Load),Output Voltage Stability:±1%(Static),Output Frequency:50/60±0.05Hz(Using Internal Oscillator),Overload Capacity:≤125% Continuous 10 min/≤150% Continuous 1 min,Display:LED Indication/Analog LCD Display/Multi-Language Support,Standard Interface:RS232×1/Smart Slot×2/Dry Contact Output×6/Dry Contact Input×2/Battery Temperature Detection×4/Battery Cabinet Status Detection×1/Parallel Interface×2/REPO×1/USB Slot×1,Peripheral Circuit:SNMP Card/Modbus Card/Analog I/O Control Card/Environmental Monitoring/SNMP Hub/Battery Temperature Detector/Battery Cabinet Status Cable,Certification:EN62040-1/CE/IEC61000-4/IEC62040-2,AC-AC Efficiency:Load Rate 50% to Full Load 94~96%/Load Rate 20% to 30% is 92~93%,ECO Mode Efficiency:Up to 99%,Battery Voltage:±240Vdc,Battery Charging Voltage:±272Vdc,Operating Temperature:0~40℃,Relative Humidity:0~95%(Non-Condensing),Audible Noise:<76dBA(1 m ahead),IP Ingress Protection:IP20,Parallel Redundancy Expansion:With (Up to 8 x),Emergency Power Off (EPO):With (Local or Remote),Dimensions:1600×865×1950mm(W×D×H),Weight:1220kg

    $147,857.14

  • Delta DPS Series: Three-Phase UPS System (UPS) - DPS-400K

    Delta DPS Series: Three-Phase UPS System (UPS) - DPS-400K

    Three-Phase UPS System (UPS),Series:Ultron DPS Series,Rated Capacity:400kVA/360kW,Input Voltage:380/220Vac(3-Phase/4 Cable+Ground),Input Voltage Range:242~477Vac,Input Current Total Harmonic Distortion:≤3%,Input Power Factor:>0.99,Input Frequency:50/60±5Hz,Output Voltage:380/220Vac(3-Phase/4 Cable+Ground),Output Voltage Harmonic Distortion:≤1.5%(Linear Load),Output Voltage Stability:±1%(Static),Output Frequency:50/60±0.05Hz(Using Internal Oscillator),Overload Capacity:≤125% Continuous 10 min/≤150% Continuous 1 min,Display:LED Indication/Analog LCD Display/Multi-Language Support,Standard Interface:RS232×1/Smart Slot×2/Dry Contact Output×6/Dry Contact Input×2/Battery Temperature Detection×4/Battery Cabinet Status Detection×1/Parallel Interface×2/REPO×1/USB Slot×1,Peripheral Circuit:SNMP Card/Modbus Card/Analog I/O Control Card/Environmental Monitoring/SNMP Hub/Battery Temperature Detector/Battery Cabinet Status Cable,Certification:EN62040-1/CE/IEC61000-4/IEC62040-2,AC-AC Efficiency:Load Rate 50% to Full Load 94~96%/Load Rate 20% to 30% is 92~93%,ECO Mode Efficiency:Up to 99%,Battery Voltage:±240Vdc,Battery Charging Voltage:±272Vdc,Operating Temperature:0~40℃,Relative Humidity:0~95%(Non-Condensing),Audible Noise:<76dBA(1 m ahead),IP Ingress Protection:IP20,Parallel Redundancy Expansion:With (Up to 8 x),Emergency Power Off (EPO):With (Local or Remote),Dimensions:1600×865×1950mm(W×D×H),Weight:1220kg

    $122,142.86

Footer image

© 2026 DELTA, .

  • US (USD $) US (USD $)
  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa